Electric_Safety_Comprehensive_Test_System
Electric Safety Comprehensive Test System (6 in 1)
  • Product class: Products Electrical Safety Tester
  • Product describe:AC withstand voltage test, insulation resistance test, leakage current test, ground resistance test, power test and voltage start up test
  • Electric Safety Comprehensive Test System (6 in 1)
    1.Features
    ● Test function: AC withstand voltage test, insulation resistance test, leakage current test, ground resistance test, power test and voltage start up test. 
    ● Meet the requirements of IEC60335-1, IEC60950, IEC60598-1, IEC60745-1 and IEC60990.
    ● Applied to household appliance, motor, electric tool and other manufacturing industries, Auto switch test functions, decrease the cost.
    ● Test accuracy: 2%
    ● Supper-big LCD display (English version), good human-machine interface.
    ● PLC control, RS232/RS485 interface port
    ● Preset warning function,  system self-checking function, auto protection function, memory analysis function

    2.Specification
    a) AC Withstand Voltage Test
    Rated output load:100VA(AC5000V/20mA)
    Range of output voltage and accuracy: 300-5000V, ± (2% setting value + 3V)
    Output frequency and accuracy: 50Hz/60Hz, ±0.2%
    Output waveform:Sine wave, crest factor= 1.3 - 1.5
    Output stability:± (1% output value + 5V), no load to full load
    Range of output current and accuracy:0.10-20.00mA, ± (2% setting value + 0.03mA)
    compensation current range and accuracy 0.0-1.00mA,± (2% setting value + 0.03mA)
    Test time and resolution: 1-999s, resolution: 1s

    b) Insulation resistance test
    Rated output load: 2VA(DC1000V/2mA)
    Range of output voltage and accuracy: DC300-1000V,± (2% setting value+ 3V)
    Output voltage ripple factor: <1%(pure resistance 1000V/1mA)
    Test range: 1.0-10.0-1000MΩ
    Accuracy:《100MΩ  ±(5%+3MΩ), >100MΩ  ±(10%+5MΩ)
    Test time and resolutio: 1-999s, resolution: 1s

    c) Ground resistance test
    No-load output voltage: <8VAC
    Range of output current and accuracy:5-30A, ± (2% setting value)
    Output current stabilit: <0.3%(10A/100mΩ)
    Range of output frequency and accuracy:50Hz/60Hz,±0.2%
    Test range and accuracy: 5-600mΩ(5-10A);2 – 200mΩ (11-25A);2–150 mΩ(26-30A);± (2%  setting value + 3mΩ)
    Test time and resolution:1-999s,resolution: 1s

    d) Leakage current test
    Range of output voltage: 1.06 times of input voltage, Pressure regulation 5%
    Range of output voltage and accuracy: 10-255VAC,± (2% reading value + 3V)
    Test range of current and accuracy:0.050~10.00mA,±(2% reading value+0.030mA)
    compensating current range and accuracy:0-0.100mA,± (2% setting value+0.030mA)
    Test time and resolution: 1-999s, resolution: 1s
    Test mode setting: dynamic/static
    Range of output power:2KW/5KW

    e) Power test
    Range of output voltage:1.0 times of input voltage, Pressure regulation 5%
    Range of output voltage and accuracy:10-255VAC,± (2% reading value+ 3V)
    Range of current and accuracy:0.10A~20.00A ±(reading value×1.0%+range×1.0%)
    Range of power:10~6000W±(reading value×1.0%+range×1.0%)
    Test time and resolution: 1-999s, resolution: 1s
    Range of output power:2KW/5KW

    f) Start up test
    Range of output voltage:0.85 times of input voltage, Pressure regulation 5%
    Test Range of output voltage and accuracy:10-255VAC, ± (2% reading value+ 3V)
    Test range of output current and accuracy: 0.10A~20.00A,±reading value×1.0%+range×1.0%)
    Test time and resolution:-999s, resolution: 1s
    Range of output power: 2KW/5KW