plug_socket_breaking_endurance_test_system
Plug Socket Breaking Endurance Test System
  • Product class: Products Plug_Socket Test Equipment
  • Product describe:plug socket breaking endurance tester
  • Plug Socket Breaking Endurance Test System
    Meet the requirements of GV2099.1 clause 20 and 21, GB15092.1, GB16915.1, IEC60884-1, IEC61058 and IEC660669-1. it is suitable for household and similar fixed electrical installations switch capacity and normal operating life test. Its aim at checking the switch whether is able to withstand the mechanical damage and electrical fatigue damage in normal use, and if there are adhesion phenomena or prolonged closed or disconnected phenomena occur, inspect whether there are excessive wear and other harmful consequences with it. It is a special equipment for switch mechanical life machine and electrical life endurance tester.
    Equipped with load(resistive, inductive, capacitive) to do load test, and equipped with corresponding control system, can do the test of button switches, toggle switches, rocker switches, push and pull switches and relevant linear switches and plug and socket life test.

    Parameter: 
    1) Power supply: AC220V±10%/50Hz
    2) Operation interface: 7 inches LCD touch screen
    3) Driver: servo motor+ ball bearing
    4) Control system: color LCD touch screen
    5) Working station: 2 stations, pneumatic, linear synchronization control
    6) Test scope: button switches, toggle switches, rocker switches, push and pull switches and relevant linear switches and plug and socket
    7) Test times: 0-999999 times, canbe preset
    8) Breakover time: 0~99.9s, can be preset
    9) Test trip: Linear: 0~100mm,adjustable
    10) Test speed rate: 15 times/min, 7.5 times/min, 30 times/min
    11) Test clamp: XYZ triaxial holder
    12) Load connection terminal: 2 channels

    Load Power
    1) Load power: 3 wires 4 lines, AC380V/50Hz (single phase AC220V, total 3 groups)
    2) stations: 2 stations
    3) Voltmeter: 0~300V, accuracy: ±0.5%
    4) Ammeter: 0~30A, accuracy: ±0.5%
    5) Powermeter: 0~10KW, accuracy: ±0.5%
    6) Power factor meter: 0.3~0.98, accuracy: ±0.5%
    7) loading method: resistive, inductive, capacitive (Switchable)
    8) Capacitive loading: 70uf, 140uf, 7.3uf optional
    9) Loading output: output load for every steps, output load for every other steps (optional)
    10) Timer: 0~999999 times (can be preset)
    11) Load capacity: 3*10KVA
    12) Output current upper limit: 30A (auto cut off @ 32A above)
    13) Output voltage upper limit: 300V (auto cut off @305V above)